Alcoris› Technical Reference› n-Hexane as SVHC

Technical Guide, Solvent Regulation

n-Hexane as SVHC: what changes for solvent buyers

Since February 2026 n-hexane is on the REACH Candidate List of substances of very high concern, and since May 2026 its harmonised classification is STOT RE 1. Both changes reach beyond hexane itself: SBP cuts, isohexane and other light aliphatic solvents can contain n-hexane too. This guide sets out what changed, which grades are affected and how to specify a low n-hexane alternative.

Reading time: ~7 min Audience: procurement, technical buyers, EHS Last updated: November 2026

Related reading: the hexane page, the 80–110 page (now ultra-low n-hexane) or the SBP cuts guide.

What changed in 2026: two separate steps

REACH Candidate List (SVHC)

On 4 February 2026 n-hexane (EC 203-777-6) was added to the REACH Candidate List of substances of very high concern, identified for specific target organ toxicity after repeated exposure (Article 57(f)). Candidate List status creates information duties in the supply chain from 0.1 wt%.

Shows up in: SDS section 15, supplier declarations, information for articles (REACH Article 33), SCIP notifications.

CLP: STOT RE 1 (H372)

With the 22nd adaptation to CLP (Delegated Regulation (EU) 2024/2564), mandatory from 1 May 2026, the harmonised classification of n-hexane moved from STOT RE 2 (H373) to STOT RE 1 (H372, nervous system), and its specific concentration limit of 5% was removed. Repr. 2 (H361f) remains.

Shows up in: SDS section 2, labels, workplace risk assessment.

Neither step bans n-hexane. Both raise the documentation and assessment burden for every product that contains it. Candidate List inclusion can be a first step towards authorisation under REACH Annex XIV, but that requires a separate decision and has not been taken for n-hexane.

Check the SDS revision date: safety data sheets issued before May 2026 may still show STOT RE 2 (H373) and no Candidate List reference. Ask for the current revision before internal approval.


Which solvents are affected: it depends on the n-hexane content

n-Hexane is the main component of hexane, but it also occurs in light SBP cuts, isohexane and some C6 naphthenic solvents. What matters is the actual content in the grade you buy, not the product name.

GradeTypical n-hexanePractical effect
Hexanemin ~44 wt%Technical and extraction grades: Repr. 2 and STOT RE 1 (H372). SVHC information duties apply.
SBP 60/95 Smax ~2 wt%Above the 0.1 wt% SVHC threshold. Check section 2 for any STOT RE classification.
SBP 80/110 ULNH<0.1 wt%Below the SVHC threshold; according to the producer, no n-hexane-related labels.
SBP 80/110, older gradesup to ~5 wt%SVHC information duties. Ask whether the supply is ULNH.
Isohexanegrade-dependentCheck the residual n-hexane on the CoA and section 2 of the SDS.
C6 naphthenictypically <5 wt%Classification varies by source. SVHC information duties above 0.1 wt%.
Heptane, light isoparaffinsgrade-dependentn-Hexane is not a design component; usually not affected. Confirm the value on the CoA.

Indicative only. Actual content and classification follow the current SDS and CoA of the specific supply.

As orientation, the CLP mixture rules give STOT RE 2 from 1 wt% and STOT RE 1 from 10 wt% of a STOT RE 1 component, and Repr. 2 from 3 wt% of a Repr. 2 component. Hydrocarbon solvents are mostly UVCB substances, which registrants classify on their own data, so section 2 of the current SDS is always decisive.


What ULNH means: ultra-low n-hexane grades

Producers have responded with ultra-low n-hexane (ULNH) versions of existing grades, with n-hexane below 0.1 wt%. In 2026 at least one European producer converted its SBP 80/110 grade completely to a ULNH version. The boiling range and the other sales specification parameters are typically unchanged, but that should be confirmed on the current sales specification rather than assumed.

For buyers the practical point is simple: the grade name on a purchase order no longer tells you which version you receive. During a transition, older SDS and specification documents can still circulate with the previous n-hexane limit.

Same name, different documents: state the maximum n-hexane content on the purchase order (for example <0.1 wt%) and ask for the CoA value per batch. That is the only way to be sure which version is delivered.


Choosing an alternative: start from the boiling range

Replacing an n-hexane-containing solvent changes evaporation, solvency and sometimes the process itself. The boiling range is the most useful starting point, as explained in the flash point vs boiling range guide.

Substitution risk: a lower n-hexane content does not make two solvents interchangeable. Evaporation rate, solvency, flash point and transport classification can all change. Test the alternative in the actual formulation or process before switching.


What to put on your purchase order or enquiry


Summary

Looking at low n-hexane grades?

Send the grade, the n-hexane limit and the volume

If you are reviewing hexane, SBP cuts or another n-hexane-containing solvent, send an enquiry with the current grade, the n-hexane limit you need, the application, volume and delivery location. The enquiry will be reviewed and, where it fits the network, forwarded to a supplier operating in the relevant category. Availability of ULNH grades depends on producer and route and is confirmed in the offer.